Ap- pear- ance |
Sensing distance |
Con- nection method |
Cable specifi- cations |
Po- lar- ity |
Opera- tion mode |
Pin ar- range- ment |
Appli- cable con- nector code *2 |
Model |
M8 | 2 mm | M12 Pre- wired Smartclick Connector Models (0.3 m) |
PUR (increased oil-resistant) |
Yes | NO | 1: +V, 4: 0 V |
H | E2E-X2D1-M1TGJ-U 0.3M |
NC | 1: +V, 2: 0 V |
E2E-X2D2-M1TGJ-U 0.3M | ||||||
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
G | E2E-X2D1-M1TGJ 0.3M | ||||
Pre-wired Models (2 m) |
PUR (increased oil-resistant) |
NO | --- | --- | E2E-X2D1-U 2M | |||
NC | E2E-X2D2-U 2M | |||||||
PVC (oil-resistant) |
NO | E2E-X2D1-N 2M | ||||||
NC | E2E-X2D2-N 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X2D1-M1G | |||
NC | 1: +V, 2: 0 V |
D | E2E-X2D2-M1G | |||||
M8 Connector Models |
--- | NO | 1: +V, 4: 0 V |
I | E2E-X2D1-M3G | |||
NC | 1: +V, 2: 0 V |
E2E-X2D2-M3G | ||||||
M12 | 3 mm | M12 Pre- wired Smartclick Connector Models (0.3 m) |
PUR (increased oil-resistant) |
Yes | NO | 1: +V, 4: 0 V |
H | E2E-X3D1-M1TGJ-U 0.3M |
NC | 1: +V, 2: 0 V |
E2E-X3D2-M1TGJ-U 0.3M | ||||||
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
G | E2E-X3D1-M1TGJ 0.3M | ||||
Pre-wired Models (2 m) |
PUR (increased oil-resistant) |
NO | --- | --- | E2E-X3D1-U 2M | |||
NC | E2E-X3D2-U 2M | |||||||
PVC (oil-resistant) |
NO | E2E-X3D1-N 2M *1 | ||||||
NC | E2E-X3D2-N 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X3D1-M1G *1 | |||
NC | 1: +V, 2: 0 V |
D | E2E-X3D2-M1G | |||||
M12 Standard Pre-wired Connector Models (0.3 m) |
PVC (oil-resistant) |
Yes | NO | 1: +V, 4: 0 V |
A | E2E-X3D1-M1GJ 0.3M | ||
NC | 1: +V, 2: 0 V |
D | E2E-X3D2-M1GJ 0.3M | |||||
No *3 | NO | (3, 4): (+V, 0 V) |
C | E2E-X3D1-M1J-T 0.3M | ||||
NC | (1, 2): (+V, 0 V) |
D | --- | |||||
M18 | 7 mm | M12 Pre- wired Smartclick Connector Models (0.3 m) |
PUR (increased oil-resistant) |
Yes | NO | 1: +V, 4: 0 V |
H | E2E-X7D1-M1TGJ-U 0.3M |
NC | 1: +V, 2: 0 V |
E2E-X7D2-M1TGJ-U 0.3M | ||||||
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
G | E2E-X7D1-M1TGJ 0.3M | ||||
Pre-wired Models (2 m) |
PUR (increased oil-resistant) |
NO | --- | --- | E2E-X7D1-U 2M | |||
NC | E2E-X7D2-U 2M | |||||||
PVC (oil-resistant) |
NO | E2E-X7D1-N 2M *1 | ||||||
NC | E2E-X7D2-N 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X7D1-M1G *1 | |||
NC | 1: +V, 2: 0 V |
D | E2E-X7D2-M1G | |||||
M12 Standard Pre-wired Connector Models (0.3 m) |
PVC (oil-resistant) |
Yes | NO | 1: +V, 4: 0 V |
A | E2E-X7D1-M1GJ 0.3M | ||
NC | 1: +V, 2: 0 V |
D | E2E-X7D2-M1GJ 0.3M | |||||
No *3 | NO | (3, 4): (+V, 0 V) |
C | E2E-X7D1-M1J-T 0.3M | ||||
NC | (1, 2): (+V, 0 V) |
D | E2E-X7D2-M1J-T 0.3M | |||||
M30 | 10 mm | M12 Pre- wired Smartclick Connector Models (0.3 m) |
PUR (increased oil-resistant) |
Yes | NO | 1: +V, 4: 0 V |
H | E2E-X10D1-M1TGJ-U 0.3M |
NC | 1: +V, 2: 0 V |
E2E-X10D2-M1TGJ-U 0.3M | ||||||
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
G | E2E-X10D1-M1TGJ 0.3M | ||||
Pre-wired Models (2 m) |
PUR (increased oil-resistant) |
NO | --- | --- | E2E-X10D1-U 2M | |||
NC | E2E-X10D2-U 2M | |||||||
PVC (oil-resistant) |
NO | E2E-X10D1-N 2M *1 | ||||||
NC | E2E-X10D2-N 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X10D1-M1G *1 | |||
NC | 1: +V, 2: 0 V |
D | E2E-X10D2-M1G | |||||
M12 Standard Pre-wired Connector Models (0.3 m) |
PVC (oil-resistant) |
Yes | NO | 1: +V, 4: 0 V |
A | E2E-X10D1-M1GJ 0.3M | ||
PVC (oil-resistant) |
NC | 1: +V, 2: 0 V |
D | E2E-X10D2-M1GJ 0.3M | ||||
PVC (oil-resistant) |
No *3 | NO | (3, 4): (+V, 0 V) |
C | E2E-X10D1-M1J-T 0.3M | |||
PVC (oil-resistant) |
NC | (1, 2): (+V, 0 V) |
D | E2E-X10D2-M1J-T 0.3M |
Ap- pear- ance |
Sensing distance |
Connection method |
Cable specifi- cations |
Po- lar- ity |
Opera- tion mode |
Pin ar- range- ment |
Appli- cable con- nector code * |
Model |
M8 | 2 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
PVC (oil- resistant) |
Yes | NO | 1: +V, 4: 0 V |
G | E2E-X2D1-M1TGJ-US 0.3M |
NC | 1: +V, 2: 0 V |
E2E-X2D2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X2D1-US 2M | ||||
NC | E2E-X2D2-US 2M | |||||||
M12 | 3 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
NO | 1: +V, 4: 0 V |
G | E2E-X3D1-M1TGJ-US 0.3M | ||
NC | 1: +V, 2: 0 V |
E2E-X3D2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X3D1-US 2M | ||||
NC | E2E-X3D2-US 2M | |||||||
M18 | 7 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
NO | 1: +V, 4: 0 V |
G | E2E-X7D1-M1TGJ-US 0.3M | ||
NC | 1: +V, 2: 0 V |
E2E-X7D2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X7D1-US 2M | ||||
NC | E2E-X7D2-US 2M | |||||||
M30 | 10 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
NO | 1: +V, 4: 0 V |
G | E2E-X10D1-M1TGJ-US 0.3M | ||
NC | 1: +V, 2: 0 V |
E2E-X10D2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X10D1-US 2M | ||||
NC | E2E-X10D2-US 2M |
Ap- pear- ance |
Sensing distance |
Con- nection method |
Cable specifi- cations |
Po- lar- ity |
Opera- tion mode |
Pin ar- range- ment |
Appli- cable con- nector code *2 |
Model |
M8 | 4 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
Yes | NO | --- | --- | E2E-X4MD1 2M |
NC | E2E-X4MD2 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X4MD1-M1G | |||
NC | 1: +V, 2: 0 V |
D | E2E-X4MD2-M1G | |||||
M8 Connector Models |
--- | NO | 1: +V, 4: 0 V |
I | E2E-X4MD1-M3G | |||
NC | 1: +V, 2: 0 V |
E2E-X4MD2-M3G | ||||||
M12 | 8 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
G | E2E-X8MD1-M1TGJ 0.3M | |
Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X8MD1 2M *1 | |||
NC | E2E-X8MD2 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X8MD1-M1G *1 | |||
NC | 1: +V, 2: 0 V |
D | E2E-X8MD2-M1G | |||||
M12 Standard Pre-wired Connector Models (0.3 m) |
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
A | E2E-X8MD1-M1GJ 0.3M | |||
NC | 1: +V, 2: 0 V |
D | --- | |||||
M18 | 14 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
G | E2E-X14MD1-M1TGJ 0.3M | |
Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X14MD1 2M *1 | |||
NC | E2E-X14MD2 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X14MD1-M1G *1 | |||
NC | 1: +V, 2: 0 V |
D | E2E-X14MD2-M1G | |||||
M12 Standard Pre-wired Connector Models (0.3 m) |
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
A | E2E-X14MD1-M1GJ 0.3M | |||
NC | 1: +V, 2: 0 V |
D | E2E-X14MD2-M1GJ 0.3M | |||||
M30 | 20 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
G | E2E-X20MD1-M1TGJ 0.3M | |
Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X20MD1 2M *1 | |||
NC | E2E-X20MD2 2M | |||||||
M12 Connector Models |
--- | NO | 1: +V, 4: 0 V |
A | E2E-X20MD1-M1G *1 | |||
NC | 1: +V, 2: 0 V |
D | E2E-X20MD2-M1G | |||||
M12 Standard Pre-wired Connector Models (0.3 m) |
PVC (oil-resistant) |
NO | 1: +V, 4: 0 V |
A | E2E-X20MD1-M1GJ 0.3M | |||
NC | 1: +V, 2: 0 V |
D | --- |
Ap- pear- ance |
Sensing distance |
Con- nection method |
Cable specifi- cations |
Po- lar- ity |
Opera- tion mode |
Pin ar- range- ment |
Appli- cable con- nector code * |
Model |
M8 | 4 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
PVC (oil- resistant) |
Yes | NO | 1: +V, 4: 0 V |
G | E2E-X4MD1-M1TGJ-US 0.3M |
NC | 1: +V, 2: 0 V |
E2E-X4MD2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X4MD1-US 2M | ||||
NC | E2E-X4MD2-US 2M | |||||||
M12 | 8 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
NO | 1: +V, 4: 0 V |
G | E2E-X8MD1-M1TGJ-US 0.3M | ||
NC | 1: +V, 2: 0 V |
E2E-X8MD2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X8MD1-US 2M | ||||
NC | E2E-X8MD2-US 2M | |||||||
M18 | 14 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
NO | 1: +V, 4: 0 V |
G | E2E-X14MD1-M1TGJ-US 0.3M | ||
NC | 1: +V, 2: 0 V |
E2E-X14MD2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X14MD1-US 2M | ||||
NC | E2E-X14MD2-US 2M | |||||||
M30 | 20 mm | M12 Pre-wired Smartclick Connector Models (0.3 m) |
NO | 1: +V, 4: 0 V |
G | E2E-X20MD1-M1TGJ-US 0.3M | ||
NC | 1: +V, 2: 0 V |
E2E-X20MD2-M1TGJ-US 0.3M | ||||||
Pre-wired Models (2 m) |
NO | --- | --- | E2E-X20MD1-US 2M | ||||
NC | E2E-X20MD2-US 2M |
Ap- pear- ance |
Sensing distance |
Con- nection method |
Cable specifi- cations |
Po- lar- ity |
Opera- tion mode |
Pin arrangement |
Appli- cable con- nector code *2 |
Model |
M12 | 3 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
Yes | NO | --- | --- | E2E-X3D1S 2M *1 |
M12 Connector Models |
--- | 2: +V and diagnostic output 3: 0 V 4: +V and control output |
D | E2E-X3D1S-M1 | ||||
M18 | 7 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
--- | --- | E2E-X7D1S 2M *1 | ||
M12 Connector Models |
--- | 2: +V and diagnostic output 3: 0 V 4: +V and control output |
D | E2E-X7D1S-M1 | ||||
M30 | 10 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
--- | --- | E2E-X10D1S 2M *1 | ||
M12 Connector Models |
--- | 2: +V and diagnostic output 3: 0 V 4: +V and control output |
D | E2E-X10D1S-M1 |
Ap- pear- ance |
Sensing distance |
Con- nection method |
Cable specifi- cations |
Po- lar- ity |
Opera- tion mode |
Pin arrangement |
Appli- cable con- nector code *2 |
Model |
M12 | 8 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
Yes | NO | --- | --- | E2E-X8MD1S 2M *1 |
M12 Connector Models |
--- | 2: +V and diagnostic output 3: 0 V 4: +V and control output |
D | E2E-X8MD1S-M1 | ||||
M18 | 14 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
--- | --- | E2E-X14MD1S 2M *1 | ||
M12 Connector Models |
--- | 2: +V and diagnostic output 3: 0 V 4: +V and control output |
D | E2E-X14MD1S-M1 | ||||
M30 | 20 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
--- | --- | E2E-X20MD1S 2M *1 | ||
M12 Connector Models |
--- | 2: +V and diagnostic output 3: 0 V 4: +V and control output |
D | E2E-X20MD1S-M1 |
Cable length |
Model |
500 mm | XS2W-D421-BY1 |
Appearance | Model | ||||
NO | Applicable connector code * |
NC | Applicable connector code * |
||
M8 | E2E-X2D1-M1 | C | E2E-X2D2-M1 | D | |
M12 | E2E-X3D1-M1 | C | E2E-X3D2-M1 | D | |
M18 | E2E-X7D1-M1 | C | E2E-X7D2-M1 | D | |
M30 | E2E-X10D1-M1 | C | E2E-X10D2-M1 | D | |
M8 | E2E-X4MD1-M1 | C | E2E-X4MD2-M1 | D | |
M12 | E2E-X8MD1-M1 | C | E2E-X8MD2-M1 | D | |
M18 | E2E-X14MD1-M1 | C | E2E-X14MD2-M1 | D | |
M30 | E2E-X20MD1-M1 | C | E2E-X20MD2-M1 | D |
Appear- ance |
Sensing distance |
Connection method |
Cable specifications |
Opera- tion mode |
Pin arrangement |
Applicable connector code *2 |
Model |
M8 | 1.5 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X1R5Y1 2M |
NC | E2E-X1R5Y2 2M | ||||||
M12 | 2 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X2Y1 2M *1 |
NC | E2E-X2Y2 2M | ||||||
M12 Connector Models |
--- | NO | (3, 4): (AC, AC) | E | E2E-X2Y1-M1 | ||
NC | (1, 2): (AC, AC) | F | E2E-X2Y2-M1 | ||||
M18 | 5 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X5Y1 2M *1 |
NC | E2E-X5Y2 2M | ||||||
M12 Connector Models |
--- | NO | (3, 4): (AC, AC) | E | E2E-X5Y1-M1 | ||
NC | (1, 2): (AC, AC) | F | E2E-X5Y2-M1 | ||||
M30 | 10 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X10Y1 2M *1 |
NC | E2E-X10Y2 2M | ||||||
M12 Connector Models |
--- | NO | (3, 4): (AC, AC) | E | E2E-X10Y1-M1 | ||
NC | (1, 2): (AC, AC) | F | E2E-X10Y2-M1 |
Appear- ance |
Sensing distance |
Connection method |
Cable specifications |
Opera- tion mode |
Pin arrangement |
Applicable connector code *2 |
Model |
M8 | 2 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X2MY1 2M |
NC | E2E-X2MY2 2M | ||||||
M12 | 5 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X5MY1 2M *1 |
NC | E2E-X5MY2 2M | ||||||
M12 Connector Models |
--- | NO | (3, 4): (AC, AC) | E | E2E-X5MY1 2M | ||
NC | (1, 2): (AC, AC) | F | E2E-X5MY2-M1 | ||||
M18 | 10 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X10MY1 2M *1 |
NC | E2E-X10MY2 2M | ||||||
M12 Connector Models |
--- | NO | (3, 4): (AC, AC) | E | E2E-X10MY1-M1 | ||
NC | (1, 2): (AC, AC) | F | E2E-X10MY2-M1 | ||||
M30 | 18 mm | Pre-wired Models (2 m) |
PVC (oil-resistant) |
NO | --- | --- | E2E-X18MY1 2M *1 |
NC | E2E-X18MY2 2M | ||||||
M12 Connector Models |
--- | NO | (3, 4): (AC, AC) | E | E2E-X18MY1-M1 | ||
NC | (1, 2): (AC, AC) | F | E2E-X18MY2-M1 |
Appear- ance |
Sensing distance |
Connection method |
Cable specifications |
Operation mode |
Pin arrange- ment |
Applicable connector code |
Model |
M12 | 3 mm | Pre-wired Models (2 m) | PVC (oil-resistant) | NO | --- | --- | E2E-X3T1 2M |
M18 | 7 mm | Pre-wired Models (2 m) | PVC (oil-resistant) | --- | --- | E2E-X7T1 2M | |
M30 | 10 mm | Pre-wired Models (2 m) | PVC (oil-resistant) | --- | --- | E2E-X10T1 2M |
Ap- pear- ance |
Sensing distance |
Con- nection method |
Cable specifi- cations |
Opera- tion mode |
Pin arrange- ment |
Appli- cable con- nector code *2 |
Model | |
NPN output | PNP output | |||||||
M8 | 1.5 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X1R5E1 2M | E2E-X1R5F1 2M |
PVC (oil- resistant) |
NC | E2E-X1R5E2 2M | E2E-X1R5F2 2M | |||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X1R5E1-M1 | E2E-X1R5F1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X1R5E2-M1 | E2E-X1R5F2-M1 | ||||
M8 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
I | E2E-X1R5E1-M3 | E2E-X1R5F1-M3 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
E2E-X1R5E2-M3 | E2E-X1R5F2-M3 | |||||
M12 | 2 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X2E1 2M *1 | E2E-X2F1 2M *1 |
NC | E2E-X2E2 2M | E2E-X2F2 2M | ||||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X2E1-M1 | E2E-X2F1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X2E2-M1 | E2E-X2F2-M1 | ||||
M18 | 5 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X5E1 2M *1 | E2E-X5F1 2M *1 |
NC | E2E-X5E2 2M | E2E-X5F2 2M | ||||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X5E1-M1 | E2E-X5F1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X5E2-M1 | E2E-X5F2-M1 | ||||
M30 | 10 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X10E1 2M *1 | E2E-X10F1 2M |
NC | E2E-X10E2 2M | E2E-X10F2 2M | ||||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X10E1-M1 | E2E-X10F1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X10E2-M1 | E2E-X10F2-M1 |
Ap- pear- ance |
Sensing distance |
Con- nection method |
Cable specifi- cations |
Opera- tion mode |
Pin arrange- ment |
Appli- cable con- nector code *2 |
Model | |
NPN output | PNP output | |||||||
M8 | 2 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X2ME1 2M | E2E-X2MF1 2M |
NC | E2E-X2ME2 2M | E2E-X2MF2 2M | ||||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X2ME1-M1 | E2E-X2MF1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X2ME2-M1 | E2E-X2MF2-M1 | ||||
M8 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
I | E2E-X2ME1-M3 | E2E-X2MF1-M3 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
E2E-X2ME2-M3 | E2E-X2MF2-M3 | |||||
M12 | 5 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X5ME1 2M *1 | E2E-X5MF1 2M |
NC | E2E-X5ME2 2M | E2E-X5MF2 2M | ||||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X5ME1-M1 | E2E-X5MF1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X5ME2-M1 | E2E-X5MF2-M1 | ||||
M18 | 10 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X10ME1 2M *1 | E2E-X10MF1 2M |
NC | E2E-X10ME2 2M | E2E-X10MF2 2M | ||||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X10ME1-M1 | E2E-X10MF1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X10ME2-M1 | E2E-X10MF2-M1 | ||||
M30 | 18 mm | Pre-wired Models (2 m) |
PVC (oil- resistant) |
NO | --- | --- | E2E-X18ME1 2M *1 | E2E-X18MF1 2M |
NC | E2E-X18ME2 2M | E2E-X18MF2 2M | ||||||
M12 Connector Models |
--- | NO | 1: +V, 3: 0 V, 4: Control output |
B | E2E-X18ME1-M1 | E2E-X18MF1-M1 | ||
NC | 1: +V, 3: 0 V, 2: Control output |
D | E2E-X18ME2-M1 | E2E-X18MF2-M1 |
Connector |
Applicable Proximity Sensor model number |
|||
Screw | Appearance *1 |
Cable length 2m | Cable length 5m | |
CablConnector model number |
CablConnector model number |
|||
M12 | Straight | XS2F-D421-DA0-F | XS2F-D421-GA0-F | E2E-X[]D1-M1G(J) |
L-shape | XS2F-D422-DA0-F | XS2F-D422-GA0-F | ||
Straight | XS2F-D421-DC0-F | XS2F-D421-GC0-F | E2E-X[]E1-M1 E2E-X[]F1-M1 |
|
L-shape | XS2F-D422-DC0-F | XS2F-D422-GC0-F | ||
Straight | XS2F-D421-DD0 | XS2F-D421-GD0 | E2E-X[]D1-M1J-T | |
E2E-X[]D1-M1 | ||||
L-shape | XS2F-D422-DD0 | XS2F-D422-GD0 | E2E-X[]D1-M1J-T | |
E2E-X[]D1-M1 | ||||
Straight | XS2F-D421-D80-F | XS2F-D421-G80-F | E2E-X[]D2-M1G(J) | |
E2E-X[]D2-M1J-T | ||||
E2E-X[]D2-M1 | ||||
E2E-X[]D1S-M1 | ||||
E2E-X[]E2-M1 E2E-X[]F2-M1 |
||||
L-shape | XS2F-D422-D80-F | XS2F-D422-G80-F | E2E-X[]D2-M1G(J) | |
E2E-X[]D2-M1J-T | ||||
E2E-X[]D2-M1 | ||||
E2E-X[]D1S-M1 | ||||
E2E-X[]E2-M1 E2E-X[]F2-M1 |
||||
Straight | XS2F-A421-DB0-F | XS2F-A421-GB0-F | E2E-X[]Y1-M1 | |
L-shape | XS2F-A422-DB0-F | XS2F-A422-GB0-F | ||
Straight | XS2F-A421-D90-F | XS2F-A421-G90-F | E2E-X[]Y2-M1 | |
Smartclick Connector, Straight |
XS5F-D421-D80-F | XS5F-D421-G80-F | E2E-X[]D1-M1TGJ(-US) | |
E2E-X[]D2-M1TGJ-US | ||||
Smartclick Connector, Straight Oil-resistant Reinforced Cables |
XS5F-D421-D80-P | XS5F-D421-G80-P | E2E-X[]D1-M1TGJ-U | |
E2E-X[]D2-M1TGJ-U | ||||
M8 | Straight | XS3F-M421-402-A | XS3F-M421-405-A | E2E-X[]D1-M3G |
E2E-X[]D2-M3G | ||||
E2E-X[]E1-M3 E2E-X[]F1-M3 |
||||
E2E-X[]E2-M3 E2E-X[]F2-M3 |
||||
L-shape | XS3F-M422-402-A | XS3F-M422-405-A | E2E-X[]D1-M3G | |
E2E-X[]D2-M3G | ||||
E2E-X[]E1-M3 E2E-X[]F1-M3 |
||||
E2E-X[]E2-M3 E2E-X[]F2-M3 |
Size | M8 | M12 | |||
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X2D[] | E2E-X4MD[] | E2E-X3D[] | E2E-X8MD[] | |
Sensing distance | 2 mm ±10% | 4 mm ±10% | 3 mm ±10% | 8 mm ±10% | |
Set distance *1 | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 2.4 mm | 0 to 6.4 mm | |
Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 20 × 20 × 1 mm |
Iron, 12 × 12 × 1 mm |
Iron, 30 × 30 × 1 mm |
|
Response frequency *2 | 1.5 kHz | 1 kHz | 0.8 kHz | ||
Power supply voltage (operating voltage range) |
Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) US Models and Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Leakage current | 0.8 mA max. | ||||
Control output |
Load current | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | |||
Residual voltage *4 |
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) | ||||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) |
||||
Operation mode (with sensing object approaching) |
D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Diagnostic output delay | 0.3 to 1 s | ||||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | ||||
Ambient temperature range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
|||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m) |
||||
Weight (packed state) |
Pre-wired Models |
Approx. 60 g | Approx. 70 g | ||
Pre-wired Connector Models |
--- | Approx. 40 g | |||
Connector Models |
Approx. 15 g | Approx. 25 g | |||
Materi- als |
Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual | ||||
Size | M18 | M30 | |||
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X7D[] | E2E-X14MD[] | E2E-X10D[] | E2E-X20MD[] | |
Sensing distance | 7 mm ±10% | 14 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
Set distance *1 | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm |
||
Response frequency *2 | 0.5 kHz | 0.4 kHz | 0.1 kHz | ||
Power supply voltage (operating voltage range) |
Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) US Models and Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Leakage current | 0.8 mA max. | ||||
Control output |
Load current | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | |||
Residual voltage *4 |
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) | ||||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) |
||||
Operation mode (with sensing object approaching) |
D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Diagnostic output delay | 0.3 to 1 s | ||||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | ||||
Ambient temperature range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m) |
||||
Weight (packed state) |
Pre-wired Models |
Approx. 130 g | Approx. 175 g | ||
Pre-wired Connector Models |
Approx. 70 g | Approx. 110 g | |||
Connector Models |
Approx. 40 g | Approx. 90 g | |||
Materi- als |
Case | Nickel-plated brass | |||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
Size | M8 | M12 | |||
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X1R5Y[] | E2E-X2MY[] | E2E-X2Y[] | E2E-X5MY[] | |
Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | ||
Set distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 12 × 12 × 1 mm | Iron, 15 × 15 × 1 mm |
||
Response frequency | 25 Hz | ||||
Power supply voltage (operating voltage range) *1 |
24 to 240 VAC (20 to 264 VAC), 50/60 Hz | ||||
Leakage current | 1.7 mA max. | ||||
Control output |
Load current *2 | 5 to 100 mA | 5 to 200 mA | ||
Residual voltage | Refer to Engineering Data on Data Sheet. | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
Y1 Models: NO Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Surge suppressor | ||||
Ambient temperature range *1 *2 |
Operating/Storage: -25 to 70°C (with no icing or condensation) |
Operating/Storage: -40 to 85°C (with no icing or condensation) |
|||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
|||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models Model |
Approx. 60 g | Approx. 70 g | ||
Connector Models | Approx. 15 g | Approx. 25 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual | ||||
Size | M18 | M30 | |||
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X5Y[] | E2E-X10MY[] | E2E-X10Y[] | E2E-X18MY[] | |
Sensing distance | 5 mm ±10% | 10 mm ±10% | 18 mm ±10% | ||
Set distance | 0 to 4 mm | 0 to 8 mm | 0 to 14 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm |
||
Response frequency | 25 Hz | ||||
Power supply voltage (operating voltage range) *1 |
24 to 240 VAC (20 to 264 VAC), 50/60 Hz | ||||
Leakage current | 1.7 mA max. | ||||
Control output |
Load current *2 | 5 to 300 mA | |||
Residual voltage | Refer to Engineering Data on Data Sheet. | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
Y1 Models: NO Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Surge suppressor | ||||
Ambient temperature range *1 *2 |
Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case |
||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models Model |
Approx. 130 g | Approx. 175 g | ||
Connector Models | Approx. 40 g | Approx. 90 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
Size | M12 | M18 | M30 | |
Shielded | Shielded | |||
Model | E2E-X3T1 | E2E-X7T1 | E2E-X10T1 | |
Sensing distance | 3 mm ±10% | 7 mm ±10% | 10 mm ±10% | |
Set distance | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 8 mm | |
Differential travel | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
|||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
Response frequency *1 |
DC | 1 kHz | 0.5 kHz | 0.4 kHz |
AC | 25 Hz | |||
Power supply voltage (operating voltage range) *2 |
24 to 240 VDC (20 to 264 VDC) 48 to 240 VAC (40 to 264 VAC) |
|||
Leakage current | DC: 1 mA max. AC: 2 mA max. |
|||
Control output |
Load current | 5 to 100 mA | ||
Residual voltage |
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m) AC: 10 V max. (Load current: 5 mA, Cable length: 2 m) |
|||
Indicators | Operation indicator (red), Setting indicator (green) | |||
Operation mode (with sensing object approaching) |
NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.) | |||
Protection circuits | Load short-circuit protection (20 to 40 VDC only), Surge suppressor | |||
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
|||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 80 g | Approx. 140 g | Approx. 190 g | |
Materials | Case | Nickel-plated brass | ||
Sensing surface | PBT | |||
Clamping nuts | Nickel-plated brass | |||
Toothed washer | Zinc-plated iron | |||
Accessories | Instruction manual |
Size | M8 | M12 | |||
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X1R5E[]/F[] | E2E-X2ME[]/F[] | E2E-X2E[]/F[] | E2E-X5ME[]/F[] | |
Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | ||
Set distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 12 × 12 × 1 mm | Iron, 15 × 15 × 1 mm |
||
Response frequency *1 | 2 kHz | 0.8 kHz | 1.5 kHz | 0.4 kHz | |
Power supply voltage (operating voltage range) *2 |
12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC) Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Current consumption | 13 mA max. | ||||
Control output |
Load current *2 | 200 mA max. | |||
Residual voltage | 2 V max. (Load current: 200 mA, Cable length: 2 m) | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
E1/F1 Models: NO E2/F2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Load short-circuit protection, Surge suppressor, Reverse polarity protection | ||||
Ambient temperature range *2 |
Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
|||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models | Approx. 65 g | Approx. 75 g | ||
Connector Models |
Approx. 15 g | Approx. 25 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual | ||||
Size | M18 | M30 | |||
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X5E[]/F[] | E2E-X10ME[]/F[] | E2E-X10E[]/F[] | E2E-X18ME[]/F[] | |
Sensing distance | 5 mm ±10% | 10 mm ±10% | 18 mm ±10% | ||
Set distance | 0 to 4 mm | 0 to 8 mm | 0 to 14 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron, 18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm |
||
Response frequency *1 | 0.6 kHz | 0.2 kHz | 0.4 kHz | 0.1 kHz | |
Power supply voltage (operating voltage range) *2 |
12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC) Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 |
||||
Current consumption | 13 mA max. | ||||
Control output |
Load current *2 | 200 mA max. | |||
Residual voltage | 2 V max. (Load current: 200 mA, Cable length: 2 m) | ||||
Indicators | Operation indicator (red) | ||||
Operation mode (with sensing object approaching) |
E1/F1 Models: NO E2/F2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Load short-circuit protection, Surge suppressor, Reverse polarity protection | ||||
Ambient temperature range *2 |
Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight (packed state) |
Pre-wired Models | Approx. 150 g | Approx. 195 g | ||
Connector Models |
Approx. 40 g | Approx. 90 g | |||
Materials | Case | Nickel-plated brass | |||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |