Communications Units for E3X-DA-N-series Fiber Amplifiers
Three New Communications Units for Fiber Amplifiers
Communications Units
Communications method |
Model |
DeviceNet |
E3X-DRT21 |
CompoBus/S |
E3X-SRT21 |
RS-422 |
E3X-CIF11 |
Terminal-block Unit
Communications method |
Model |
All communications methods |
E39-TM1 |
Fiber Amplifier with Incident Level Monitoring Function*1, 2
Communications method |
Model |
All communications methods |
E3X-DA6-P |
Wiring-reduction Connector*1
Communications method |
Model |
--- |
E3X-CN02 |
Communications Units
Model |
E3X-DRT21 |
E3X-SRT21 |
E3X-CIF11 |
Communications method |
DeviceNet |
CompoBus/S |
RS-422 |
Connectable Fiber Amplifiers *1 |
*2 E3X-DA6 *3, E3X-DA8 *3, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8 |
E3X-DA6TW *3, E3X-DA8TW *3, E3X-DA6-P *3, E39-TM1 |
Number of connectable Fiber Amplifiers |
16 max. |
14 max. |
16 max. |
Power supply voltage |
11 to 25 VDC |
14 to 26.4 VDC |
11.4 to 26.4 VDC
(12 VDC -5% to 24 VDC +10%) |
Internal current consumption *4 |
70 mA max. |
30 mA max. |
40 mA max. |
Ambient temperature |
Operating: -20 to 55°C, Storage: -30 to 70°C (with no icing or condensation) |
Ambient humidity |
35% to 85% (with no condensation) |
Weight (packed state) |
Approx. 150 g |
Approx. 200 g |
*1. Connection is not supported for Pre-wired Amplifiers (e.g., E3X-DA11-N) and water-resistant Amplifiers
(e.g., E3X-DA11V).
*2. Connection is supported for products manufactured on or after the date shown below (indicated with the lot number).
Connection is also supported for models with "MADE IN JAPAN" on the cover underlined.
*3.Manufacturing of the E3X-DA[]TW Series was discontinued at the end of March 2012. Manufacture of the
E3X-DA6/DA8/DA6-P will be discontinued in March 2017.
*4. Does not include the current supplied to the Fiber Amplifier.
Terminal-block Unit
Model |
E39-TM1 |
Power supply voltage *1 |
12 to 24 VDC ±10%, ripple (p-p) 10% max. |
Sensor power supply |
11 to 23 VDC (power supply voltage -1 V) |
Current consumption |
40 mA max. + Sensor current consumption (total: 100 mA max.) |
Response speed |
1.2 ms max. |
Number of inputs |
1 point |
Input signals |
NPN/PNP no-voltage input (contact and non-contact), switchable |
Input operating configuration |
N.O./ N.C., switchable |
Indicators |
Input signal display (orange) |
Ambient temperature *2 |
Operating:
Groups of 1 to 3 Units: -25 to 55°C (with no icing or condensation)
Groups of 4 to 8 Units: -25 to 45°C (with no icing or condensation)
Groups of 9 to 16 Units: -25 to 40°C (with no icing or condensation)
Storage: -30 to 70°C |
*1. The power supply for the E39-TM1 is provided from the Communications Unit (order separately). Use an E3X-CN02
(order separately) Connector.
*2. When 4 or more Units are grouped together, the current consumption per Unit must not exceed 75 mA.
When using together with the E3X-DA-N Fiber Amplifiers, connect the E39-TM1 Units at the end of the group.
In this case, the upper limit for the ambient temperature for the E3X-DA-N Amplifiers is the rated upper limit -5°C.
Communications Units
E3X-DRT21
E3X-SRT21
E3X-CIF11
Terminal-block Unit
E39-TM1