Omron sensors. E32-LT35Z Fiber Unit Build-in Lens Series, Flat Model
E32-LT35Z

Optical Axis Adjustment in 20 Sec and Ultra-high-power Beam Greatly Reduce Installation and Maintenance Work

Through-beam Fiber Units

Sensingdirection Appearance(mm) Bendingradius
of cable
(mm)
Cablelength Sensing distance(mm) *1 Optical axisdiameter
(minimum sensing
object) (mm) *2
Model
E3X-HD E3NX-FA
Flat-view 3462_lu_1_1
IP40
R1 2 m GIGA: 2,400
HS: 800
ST: 1,200
SHS: 300
GIGA: 3,600
HS: 1,200
ST: 1,800
SHS: 300
3 dia.
(0.1 dia./0.03 dia.)
E32-LT35Z 2M
*1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
*2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode with
the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.

Installation Information

Model Installation Cable Weight(packed
state)
Ambienttemper-
ature
Tight-ening
torque
Mount-ing
hole
Bend-ing
radius
Un-bend-
able
length
Tensilestrength Sheathmaterial Coremate-
rial
Emitter/receiver
differen-
tiation
E32-LT35Z 2M -40 to
70°C
0.15 N·m - R1 0 9.8 N Polyeth-
ylene
Plastic None Approx.
25 g
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.

E32-LT35Z (Free Cutting)

E32-LT35Z Dimensions 2