Output Form | Operating Distance (mm) | Output Form | Model Number | Remarks | ||||||
Resin Cylinder M22 | Non-flush Mount Type | NPN NO | CS-31-5N* | |||||||
5 | ||||||||||
Metal Cylinder M30 | Non-flush Mount Type | DC voltage | CS-85-15T | |||||||
15 | ||||||||||
NPN NO | CS-85-15N | |||||||||
Square type | Non-flush Mount Type | DC voltage | CS-16-5T | |||||||
5 | ||||||||||
NPN NO | CS-16-5N | |||||||||
10 | NPN NO | CS10-34CU-E | ||||||||
Effective Operating Distance | 5 mm ±10% | 15 mm ±10% | |||
Photo | |||||
Remarks | Resin Cylinder Type | Metal Cylinder Type | |||
Output Form |
DC Voltage |
Model Number | CS-85-15T | ||
Price | Open | ||||
NPN NO | Model Number | CS-31-5N* | CS-85-15N | ||
Price | Open | Open | |||
Rated Working Voltage | DC Voltage Output Type | 12 V DC (10 to 16 V DC) Allowable ripple rate: 10% p-p or less | |||
DC Switching type (N Type) |
24 V DC (20 to 30 V DC) Full wave rectification power supply can be used. (20 to 30 V DC mean value) |
12/24 V DC (10 to 30 V DC) Full wave rectification power supply can be used. (10 to 30 V DC mean value) |
|||
No-load Current | T type: 27 mA or lower N type: 20 mA or lower | ||||
Standard Target Object (mm) | Iron 50 x 50 x 1 t (Grounding state) | ||||
Reaction Material | Iron/Non ferrous metal/Non-metal (Operating distance changes depending on materials.) | ||||
Effective Operating Distance | The operating distance can be changed from a multi-rotation volume. | ||||
Hysteresis | Approx. 20% | ||||
Operating Cycle Frequency | 50 Hz | ||||
Output | T Type | Output impedance: 1.8 kK (Output standard: 8P6N) | |||
N Type Rated Working Current |
100 mA (Load voltage: Not more than 50 V) | ||||
Voltage Drop (N Type) | 2.0 V or lower | ||||
Off-state Current (N Type) | 200 µA or less | ||||
Indicator Lamp | Operation indication | ||||
Use Ambient Temperature | -25 to +70˚C | ||||
Temperature Characteristics | Within ±20% (At the operating distance at +20˚C) | ||||
Withstand Voltage | 500 V AC 50/60 Hz (1 minute) | ||||
Insulation Resistance | 5 MK or higher (500 V DC) | ||||
Vibration Resistance | Double amplitude: 1.5 mm, 10 to 55 Hz (2 h each for X, Y and Z direction) | ||||
Impact Resistance | 600 m/s2, within 11 ms (10 times each for X, Y and Z direction) | ||||
Protection Level | IP65 | ||||
Case Material | Polycarbonate | Brass nickel plate (Detector surface: Polycarbonate) |
|||
Lead Wire | Oilproof vinyl chloride cable 1.5 m Outside diameter (Approx. φ4.5) 0.3 mm2, 3 core |
Oilproof vinyl chloride cable 2 m Outside diameter (Approx. φ6) 0.5 mm2, 3 core |
|||
Tightening Torque | 3 Nm or less | 20 Nm or less | |||
Weight (g) | Approx. 80 | Approx. 250 |
Effective Operating Distance | 10 mm ±10% | 5 mm ±10% | |||
Photo | |||||
Remarks | Square type | Square type | |||
Output Form |
DC Voltage |
Model Number | CS-16-5T | ||
Price | Open | ||||
NPN NO | Model Number | CS10-34CU-E | CS-16-5N | ||
Price | Open | Open | |||
Rated Working Voltage |
12/24 V DC (10 to 30 V DC) Allowable ripple rate: 3% p-p or less |
T type: 12 V DC (10 to 16 V DC) Allowable ripple rate: 10% p-p or less |
|||
N type: 12/24 V DC (10 to 30 V DC) Full wave rectification power supply can be used. (10 to 30 V DC mean value) |
|||||
No-load Current | 20 mA or lower | T type: 27 mA or lower N type: 20 mA or lower | |||
Standard Target Object (mm) | Iron 50 x 50 x 1 t (Grounding state) | ||||
Reaction Material | Iron/Non ferrous metal/Non-metal (Operating distance changes depending on materials.) | ||||
Effective Operating Distance | 10 mm ±10% | The operating distance can be changed from a multi-rotation volume. | |||
Hysteresis | Approx. 20% or less | Approx. 20% | |||
Operating Cycle Frequency | Up to 10 Hz | 50 Hz | |||
Output | T Type | Output impedance: 1.8 kK (Output standard: 8P6N) | |||
N/E Type Rated Working Current | E type: Up to 100 mA | N type: 100 mA (Load voltage: Not more than 50 V) | |||
Voltage Drop | 2.0 V or lower (Excluding CS-16-5T) | ||||
Off-state Current | 200 µA or less (Excluding CS-16-5T) | ||||
Indicator Lamp | Operation indication | ||||
Use Ambient Temperature | -10 to +55˚C | ||||
Temperature Characteristics | Within ±15% (At the operating distance at +23˚C) | Within ±20% (At the operating distance at +20˚C) | |||
Withstand Voltage | 500 V AC 50/60 Hz (1 minute) | ||||
Insulation Resistance | 50 MK or higher (500 V DC) | 5 MK or higher (500 V DC) | |||
Vibration Resistance | Double amplitude: 1.5 mm, 10 to 55 Hz (2 h each for X, Y and Z direction) | ||||
Impact Resistance | 490 m/s2 | 600 m/s2 | |||
Within 11 ms (10 times each for X, Y and Z direction) | |||||
Protection Level | IP66 | IP50 (Dust-resistant) | |||
Case Material | PBT | Aluminum (Detector surface: Polycarbonate) |
|||
Lead Wire | Oilproof vinyl chloride cable 2 m Outside diameter (Approx. φ3.8) 0.3 mm2, 3 core |
Oilproof vinyl chloride cable 1.5 m Outside diameter (Approx. φ4) 0.3 mm2, 3 core |
|||
Tightening Torque | 0.4 Nm or less | 0.8 Nm or less | |||
Weight (g) | Approx. 80 | Approx. 100 |
Potentiometer for Adjusting the Operating Distance A multi-rotation potentiometer for adjusting the operating distance is equipped on the back of the main body of capacitance proximity sensors. After the capacitance proximity sensor is installed, use this multi-rotation potentiometer to adjust the operating distance to the standard distance for the grounded metal plate or larger standard target object (50 x 50 x 1 t mm) or below the standard distance, according to the usage. If the multi- rotation potentiometer is turned to the right, the operating distance becomes longer, and if it is turned to the left, the operating distance becomes shorter. Although the potentiometer can be adjusted 16±5 turns, even if it is turned too much, there will be no damage because the potentiometer turns idly without stopping at that point. Note that, if the operating distance is set more than the rated operating distance, operation becomes unstable. (Except for the CS10-34CU-E) Material Characteristics Even if the same material is detected, the operating distance differs by size and shape of the target object. The table below shows examples of how the operating distance differs by the type of material and shape when detected by a capacitance proximity sensor. (Detection distances differ according to the electrical conductivity, relative permittivity and the water absorption state and volume.) |
Precautions Pay careful attention to the possibility of condensation and freezing of the detector surface and the adhesion of water, oil, and dust to the detector surface because they may cause malfunction. Note that the adherence of fluid material and powder in a non-metal container may cause malfunction. Three M4 screws are used for installing the CS-16-5T and CS-16-5N. Ensure that the screws do not penetrate the case more than 6 mm. In the case of a 3-wire DC proximity sensor, a load with large making current (making current of 100 mA or more, such as a lamp, motor, and solenoid) may deteriorate or damage the switching element. In such case, use the sensor via a relay. |