TRD-2E. Энкодеры (датчики положения) KOYO.
- Особо компактный тип, 2E.
- Маленький корпус с диаметром 40 мм и глубиной 36 мм.
- Защита от обратного подключения и короткого замыкания.
- Степень защиты IP54 (пыле- и влагонепроницаемый).
Model Number List
Type |
Appearance |
Model Number |
Supply Voltage |
Output |
Output Form |
Количество импульсов на оборот |
Shaft Type |
TRD-2E□A |
4.5 to 13.2 V DC |
Output with 2-phase origin (Origin reverse action ) |
Open collector output |
10, 20, 30, 40, 50, 60, 100, |
|
TRD-2E□B |
10.8 to 26.4 V DC |
|||||
TRD-2E□V |
4.75 to 5.25 V DC |
Output with 2-phase origin (Origin direct action ) |
Line driver output |
Pulse and Frequencies
Количество импульсов на оборот |
10 |
20 |
30 |
40 |
50 |
60 |
100 |
200 |
240 |
250 |
300 |
360 |
400 |
500 |
512 |
600 |
800 |
1,000 |
1,024 |
1,200 |
2,000 |
2,500 |
3,600 |
|
Maximum Response Frequency (kHz)* |
0.8 |
1.6 |
2.5 |
3.3 |
4.1 |
5.0 |
8.3 |
16 |
20 |
20 |
25 |
30 |
33 |
41 |
42 |
50 |
66 |
83 |
85 |
100 |
166 |
200 |
200 |
|
Applicable Models |
TRD-2E□A |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
TRD-2E□B |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
TRD-2E□V |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Electrical Specifications
Model Number |
TRD-2E□A/B |
TRD-2E□V |
||
Power Supply |
Supply Voltage* |
A: 4.5 to 13.2 V DC/B: 10.8 to 26.4 V DC |
4.75 to 5.25 V DC |
|
Allowable Ripple |
3% rms or less |
|||
Consumption Current (No Load) |
50 mA or lower |
|||
Output Waveform |
Signal Format |
2-phase output + home position |
||
Maximum Response Frequency |
200 kHz |
|||
Maximum Response Number of Revolutions |
(Maximum Response Frequency/Resolution) x 60 |
|||
Duty Ratio |
50±25% |
|||
Signal Width at Home Position |
100±50% |
|||
Output |
Rise / Fall Time |
Not larger than 1 µs (Cable length 1 m, maximum load) |
||
Output Form |
NPN open collector output |
Line driver output (Equivalent to 26C31) |
||
Output Logic |
Negative logic (Active low) |
Positive logic (Active high) |
||
Output Current |
Sink |
Up to 30 mA |
Up to 20 mA |
|
Source |
̶ |
Up to 20 mA |
||
Output Voltage |
"H" |
̶ |
2.5 V or higher |
|
"L" |
0.4 V or lower |
0.5 V or lower |
||
Load Supply Voltage |
30 V DC or lower |
̶ |
||
Short-circuit Protection |
Between output and power supply |
̶ |
Mechanical Specifications
Starting Torque |
0.01 N・m or less (+20˚C) |
Moment of Inertia |
0.3 x 10-6 kg・m2 |
Shaft Allowable Load |
Radial: 30N |
Thrust: 20N |
|
Maximum Allowable Number of Revolutions (Note 1) |
5,000 rpm |
Cable |
Outside diameter φ5 mm |
Weight |
Approx. 110 g (With 1 m cable) |
Environmental Requirements
Use Ambient Temperature |
-10 to +70˚C |
Storage Ambient Temperature |
-25 to +85˚C |
Use Ambient Humidity |
35 to 85% RH (No condensation) |
Withstand Voltage |
Excluded due to capacitor grounding* |
Insulation Resistance |
50 MK or higher* |
Vibration Resistance (Endurance) |
Displacement half amplitude: |
Impact Resistance (Endurance) |
490m/s2 |
Protective Structure |
Dustproof type・Splash-proof type: IP54 |