Appearance | Sensing distance | Output configuration | Operation mode | Model | |||
Shielded |
M12 | 2 mm | DC 2-wire | NO | E2FQ-X2D1 2M | ||
DC 3-wire, NPN | E2FQ-X2E1 2M | ||||||
M18 | 5 mm | DC 2-wire | E2FQ-X5D1 2M | ||||
DC 3-wire, NPN | E2FQ-X5E1 2M | ||||||
AC 2-wire | E2FQ-X5Y1 2M | ||||||
M30 | 10 mm | DC 2-wire | E2FQ-X10D1 2M | ||||
DC 3-wire, NPN | E2FQ-X10E1 2M | ||||||
AC 2-wire | E2FQ-X10Y1 2M | ||||||
Model | E2FQ-X2E1 E2FQ-X2D1 |
E2FQ-X5E1 E2FQ-X5D1, E2FQ-X5Y1 |
E2FQ-X10E1 E2FQ-X10D1, E2FQ-X10Y1 |
||||
Sensing distance | 2 mm ±10% | 5 mm ±10% | 10 mm ±10% | ||||
Set distance | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | ||||
Differential travel | E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance | ||||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) | ||||||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | ||||
Response frequency * | E1 Models: 1.5 kHz D1 Models: 800 Hz |
E1 Models: 600 Hz D1 Models: 500 Hz |
E1 Models: 400 Hz D1 Models: 300 Hz |
||||
Y1 Models: 25 Hz | |||||||
Power supply voltage (operating voltage range) |
E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max. |
||||||
Current consumption | E1 Models: 17 mA max. | ||||||
Leakage current | D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC) | ||||||
Control output |
Load current |
E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA | |||||
Residual voltage |
E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m) Y1 Models: Refer to Engineering Data on Data Sheet. D1 Models: 3 V max. (Load current: 100 mA, Cable length: 2 m) |
||||||
Indicators | E Models: Detection indicator (red), Y Models: Operation indicator (red), D Models: Operation indicator (red), Setting indicator (green) (NO only) |
||||||
Operation mode (with sensing object approaching) |
E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.) | ||||||
Protection circuits | E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge suppressor | ||||||
Ambient temperature range |
Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||||
Voltage influence | E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range D1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range Y1 Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range |
||||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||||
Dielectric strength | E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case |
||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | ||||||
Connection method | Pre-wired Models (Cable length: 2 m) | ||||||
Weight (packed state) | Approx. 70 g | Approx. 130 g | Approx. 170 g | ||||
Materials | Case | Fluororesin | |||||
Sensing surface |
|||||||
Clamping nuts |
|||||||
Toothed washer |
Zinc-plated iron | ||||||
Cable | Vinyl chloride | ||||||
Accessories | Instruction manual |