Omron Proximity Sensors. Cylindrical. E2E-[]-IL[]

IO-Link Proximity Sensor (Standard Models)
E2E-[]-IL[]

IO-Link Makes Sensor Level Information Visible and Solves the Three Major Issues at Manufacturing Sites! Standard Proximity Sensor.

DC 3-wire IO-Link Models

Appearance Sensing
distance
Connection method Pin
arrangement
IO-Link
baud rate
Model
PNP
Shielded
3543_lu_1_1
M12 3 mm Pre-wired Models
(2 m)
-- COM2 (38.4 kbps) E2E-X3B4-IL2 2M
COM3 (230.4 kbps) E2E-X3B4-IL3 2M
M12 Pre-wired
Smartclick Connector
Models (0.3 m)
1: +V
3: 0 V
4: C/Q output
COM2 (38.4 kbps) E2E-X3B4-M1TJ-IL2 0.3M
COM3 (230.4 kbps) E2E-X3B4-M1TJ-IL3 0.3M
M18 7 mm Pre-wired Models
(2 m)
-- COM2 (38.4 kbps) E2E-X7B4-IL2 2M
COM3 (230.4 kbps) E2E-X7B4-IL3 2M
M12 Pre-wired
Smartclick Connector
Models (0.3 m)
1: +V
3: 0 V
4: C/Q output
COM2 (38.4 kbps) E2E-X7B4-M1TJ-IL2 0.3M
COM3 (230.4 kbps) E2E-X7B4-M1TJ-IL3 0.3M
M30 10 mm Pre-wired Models
(2 m)
-- COM2 (38.4 kbps) E2E-X10B4-IL2 2M
COM3 (230.4 kbps) E2E-X10B4-IL3 2M
M12 Pre-wired
Smartclick Connector
Models (0.3 m)
1: +V
3: 0 V
4: C/Q output
COM2 (38.4 kbps) E2E-X10B4-M1TJ-IL2 0.3M
COM3 (230.4 kbps) E2E-X10B4-M1TJ-IL3 0.3M
Note: Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).

Accessories (Sold Separately)

Sensor I/O Connectors

(Models with Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)

Type Appearance Cable length Sensor I/O Connector
model number
Applicable Proximity Sensor
model number
Socket on one
cable end
Straight
3543_lu_2_1
2 m XS5F-D421-D80-F E2E-X[]B4-M1TJ-IL[]
5 m XS5F-D421-G80-F
L-shape
3543_lu_2_2
2 m XS5F-D422-D80-F
5 m XS5F-D422-G80-F
Socket and plug
on cable ends *
Straight/straight
3543_lu_2_3
2 m XS5W-D421-D81-F
5 m XS5W-D421-G81-F
L-shape/L-shape
3543_lu_2_4
2 m XS5W-D422-D81-F
5 m XS5W-D422-G81-F
Note: Refer to Sensor I/O Connector/Sensor Controller for details.
* There are also straight type/L-shape type combinations available.

DC 3-wire IO-Link Models (E2E-X[]B4-IL[])

Item Size M12 M18 M30
Shielded Shielded
Model E2E-X3B4-IL[] E2E-X7B4-IL[] E2E-X10B4-IL[]
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance *1 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal
(The sensing distance decreases with non-ferrous metal. Refer to Engineering
Data on Catalog.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *2 1 kHz 0.5 kHz 0.4 kHz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p))
Current consumption 20 mA max.
Control output Load current 100 mA max.
Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators *1 In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability
indicator (green, lit)
In the IO-Link mode: Operation indicator (orange, lit) and communication indicator
(green, blinking at 1 s intervals)
Operation mode PNP NO/NC switching type (Factory setting: NO)
Refer to the timing charts under I/O Circuit Diagrams on Catalog for details.
Protection circuits Power supply reverse polarity protection, output reverse polarity protection, surge
suppressor, and output short-circuit protection
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant *3
Connection method Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m)
Materials Case Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Main IO-Link functions Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and
timer time selecting, instability output (IO-Link mode) ON delay timer time selecting
function, monitor output, operating hours read-out, and initial reset
Communication
specifications
IO-Link
specification
Ver 1.1
Baud rate -IL3: COM3 (230.4 kbps), -IL2: COM2 (38.4 kbps)
Data length PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum cycle
time
-IL3 (COM3): 1 ms, -IL2 (COM2): 2.3 ms
Accessories Instruction manual
Note: Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file).
*1. In the Standard I/O mode (SIO mode), use the product in a range that the green stability indication lamp is lit. (Although the lamp is turned off when the object detected has approached excessively, the detection performance is stable.)
In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.) Please contact your OMRON sales representative regarding assignment of data.
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. Oil resistance in-house standard: Performance with respect to water insoluble oil.
(Test at below)

Oil resistance test

After the test time elapses, the characteristics below are checked for problems.
(1) Visual appearance (no damage that affects product characteristics)
(2) Operation check (ON/OFF) (3) Insulation resistance (50 MΩ min. at 500 VDC)
(4) Dielectric strength (500 VAC, 1 min.)
(5) Water resistance (IP67)
E2E-[]-IL[] Specifications 3

Pre-wired Models

E2E-X3B4-IL[]

E2E-[]-IL[] Dimensions 2
*1. 4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m
*2. Operation indicator (orange), stability indicator/communication indicator (green)

E2E-X7B4-IL[]

E2E-[]-IL[] Dimensions 3
*1. 6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
*2. Operation indicator (orange), stability indicator/communication indicator (green)

E2E-X10B4-IL[]

E2E-[]-IL[] Dimensions 4
*1. 6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
*2. Operation indicator (orange), stability indicator/communication indicator (green)

Pre-wired Connector Models

E2E-X3B4-M1TJ-IL[]

E2E-[]-IL[] Dimensions 6
*1. 4-dia. vinyl-insulated round cable Standard length: 0.3 m
*2. Operation indicator (orange), stability indicator/communication indicator (green)

E2E-X7B4-M1TJ-IL[]

E2E-[]-IL[] Dimensions 7
*1. 6-dia. vinyl-insulated round cable Standard length: 0.3 m
*2. Operation indicator (orange), stability indicator/communication indicator (green)

E2E-X10B4-M1TJ-IL[]

E2E-[]-IL[] Dimensions 8
*1. 6-dia. vinyl-insulated round cable Standard length: 0.3 m
*2. Operation indicator (orange), stability indicator/communication indicator (green)

Mounting Hole Dimensions

E2E-[]-IL[] Dimensions 9