Omron sensors. E32-L11FP / L1[]FS, E3X-DA[][]TG-S.

Wet Process Sensor
E32-L11FP / L1[]FS, E3X-DA[][]TG-S

Stable Detection of Glass in Wet Processes. Non-contact Operation Simplifies Mounting and Maintenance.

Type Appearance
(mm) *
Sensing distance (mm) Standard
object
Min.
bending
radius
(mm)
Features Model
Limited-
reflective
(Free-cut)
8 to 20 mm from the lens tip
(recommended sensing distance:
11 mm)
19 to 31 mm from the center of
mounting hole A (recommended
sensing distance: 22 mm)
(See the dimension drawings.)
Glass
(t =
0.7 mm)
R40 Materials:
Heat-resistant
PVC and
fluororesin
IP67 at 60°C
E32-L11FP 2M
E32-L11FP 5M
(Free-cut)
8 to 20 mm from the lens tip
(recommended sensing distance:
11 mm)
32 to 44 mm from the center of
mounting hole A (recommended
sensing distance: 35 mm)
(See the dimension drawings.)
Materials:
SUS316L and
fluororesin
IP67 at 85°C
E32-L11FS 2M
E32-L11FS 5M
Materials:
SUS316L and
fluororesin
IP67 at 70°C
E32-L12FS 2M
E32-L12FS 5M
* (Free-cut) Indicates models that allow free cutting.

Amplifier Units

Appearance Connection
method
Functions Model
NPN output PNP output
Pre-wired model
(2 m)
Tough Mode
Super Tough Mode
ON-delay and OFF-delay timer
E3X-DA11TG-S 2M E3X-DA41TG-S 2M
Model E3X-DA11TG-S E3X-DA41TG-S
Output NPN open-collector output PNP open-collector output
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Control output Load power supply voltage: 26.4 VDC, load current: 50 mA max.;
residual voltage: 1 V max.
Response time Tough Mode (TG):
Operate/reset in 16 ms each, Super Tough Mode (STG): Operate/reset in 64 ms each
Standard Mode (STND):
Operate/reset in 1 ms each, High-resolution Mode (HRES) Operate/reset in 4 ms each
Timer function ON-delay/OFF-delay timer, OFF-delay timer, ON-delay timer, one-shot timer
Note 1: The factory settings are as follows: Tough Mode with an ON-delay/OFF-delay timer.
2: Be sure to check the chemicals and sprays used in the ambient environment before using the Wet Sensor.

E32-L11P

E32-L11FP / L1[]FS, E3X-DA[][]TG-S Dimensions 1

E32-L11FS
E32-L12FS

E32-L11FP / L1[]FS, E3X-DA[][]TG-S Dimensions 2

E3X-DA11TG-S
E3X-DA41TG-S

E32-L11FP / L1[]FS, E3X-DA[][]TG-S Dimensions 3